| Rating |
200 deg C, 300 Vac, Horizontal Flame, Oil Resistant 80 deg C (optional). |
| |
| Insulation |
Labeled or complying with manufacturer's AWM Procedure and having a minimum rating of 200 C and 300 volts. The designations of all styles of individual conductors used in making up the cable assembly shall be available. |
| |
| Shield |
Optional. |
| |
| Jacket |
Extruded FEP, 20 mils minimum average thickness, 16 mils minimum thickness at any point. |
| |
| Standard |
Appliance Wiring Material UL 758. |
| |
| Marking |
General. |
| |
| Use |
Internal wiring of appliances or electronic equipment. In addition, the tag may also indicate the following: 600 volts peak -- For Electronic Use Only. |
| |